Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:aree:epr:attivita:radiazioni_ionizzanti [2018/08/11 16:27]
Gianluca Frustagli
en:aree:epr:attivita:radiazioni_ionizzanti [2020/10/30 15:54] (current)
Gianluca Frustagli [Identification of irradiated foods]
Line 3: Line 3:
 ====== Ionizing radiation ====== ====== Ionizing radiation ======
  
-{{:​aree:​epr:​attivita:​radiazioni_ionizzanti.svg?​160 |}} //Ionizing and non-ionizing radiations induce stable radicals in solid matrices. EPR allows a qualitative and quantitative evaluation of such radiation-induced radicals which act as indicators of exposure. A quantitative assessment of the exposure can be obtained by using a calibration curve.//+Ionizing and non-ionizing radiations induce stable radicals in solid matrices. EPR allows a qualitative and quantitative evaluation of such radiation-induced radicals which act as indicators of exposure. A quantitative assessment of the exposure can be obtained by using a calibration curve.
  
-//Possible fields of application are:// +Possible fields of application are:
- +
-\\ \\ \\ \\ \\+
  
 ===== Identification of irradiated foods ===== ===== Identification of irradiated foods =====
Line 20: Line 18:
  
 Two other physical methods based on stimulated luminescence are available. Two other physical methods based on stimulated luminescence are available.
 +
 +\\
  
 > Contact: [[emanuela.bortolin@iss.it|Emanuela Bortolin]] > Contact: [[emanuela.bortolin@iss.it|Emanuela Bortolin]]
 > ☎ **+39 06 4990 3634** > ☎ **+39 06 4990 3634**
  
- +\\ \\
-===== Dose estimate in radiation emergencies and epidemiological studies ​ ===== +
- +
-EPR can be used to identify exposures occurred during accidental nuclear and radiological events (radiological equipment malfunctions or harmful use of ionizing radiation) when conventional personal dosimeters are absent or inadequate. Radio-induced defects on everyday objects such as clothing or screens of mobile phones, or on biological tissues such as nails or teeth, can be used as indicators of accidental exposure and, through the use of calibration curves, as an instrument of evaluation of the absorbed radiation dose. +
- +
-Reconstruction of the individual dose finds application in: +
- +
-  * the assessment of the risk of radiation in individuals exposed to accidental events to prevent their harmful effects and provide any necessary medical treatment;​ +
-  * the estimation of radiation risk factors through the study of epidemiological cohorts in which the health effects are related to the absorbed dose values. +
- +
- +
-> Contact: [[paola.fattibene@iss.it|Paola Fattibene]] +
-> ☎ **+39 06 4990 2483** +
- +
 ===== Dosimetry in radiotherapy ​ ===== ===== Dosimetry in radiotherapy ​ =====
  
Line 45: Line 31:
 Other medical dosimetry systems are also available in the area. Other medical dosimetry systems are also available in the area.
  
-{{aree:​epr:​attivita:​sistema_dosimetrico_alanina-epr.png?​300|}} ​\\ <wrap lo>​Alanine/​EPR dosimetric system</​wrap>​+\\
  
 > Contact: [[cinzia.deangelis@iss.it|Cinzia De Angelis]] > Contact: [[cinzia.deangelis@iss.it|Cinzia De Angelis]]
 > ☎ **+39 06 4990 2248** > ☎ **+39 06 4990 2248**
  
-> FIXME **To be revised.**\\ //(remove this paragraph once finished)//+/* > FIXME **To be revised.**\\ //(remove this paragraph once finished)// */