Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:aree:epr:altre_risorse:start [2020/10/30 18:51]
Paola Fattibene
en:aree:epr:altre_risorse:start [2024/04/24 19:24] (current)
Gianluca Frustagli [Surface Plasmon Resonance (SPR - Biacore)] New contact.
Line 19: Line 19:
  
 ===== Stimulated Luminescence instrumentation ===== ===== Stimulated Luminescence instrumentation =====
 +
 \\ \\
 +
 === Thermoluminescence reader === === Thermoluminescence reader ===
-{{aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-num.jpeg?​300|Thermoluminescence reader + laboratory oven for thermal treatments}} {{:​aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-dett.jpeg?​300|Detail of thermoluminescence reader}} + 
-\\ \\ +{{aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-num.jpeg?​300 |Thermoluminescence reader + laboratory oven for thermal treatments}} {{:​aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-dett.jpeg?​300 |Detail of thermoluminescence reader}} Thermoluminescence reader Harshaw, mod. 3500 equipped with software WinREMS for data acquisition and analysis. Thermal cycles up to 600°C (with an uncertainty of +/-1%) with different heating rates, including isothermal decays. Laboratory oven specially designed for TL dosimetry. Run by a microprocessor,​ it allows heating of the sample at controlled temperatures. Different heating cycles available by the dedicated software. 
-\\ Thermoluminescence reader Harshaw, mod. 3500 equipped with software WinREMS for data acquisition and analysis. Thermal cycles up to 600°C (with an uncertainty of +/-1%) with different heating rates, including isothermal decays. Laboratory oven specially designed for TL dosimetry. Run by a microprocessor,​ it allows heating of the sample at controlled temperatures. Different heating cycles available by the dedicated software.+
 \\ \\
 \\ \\
 +
 === Optically stimulated luminescence reader === === Optically stimulated luminescence reader ===
 +
 {{:​aree:​epr:​altre_risorse:​lettore_osl-tl_riso_da-20.jpeg?​300 |OSL/TL reader}} OSL/TL reader Risø DA-20 (DTU Nutech, Danimarca) equipped with a carousel loading up to 48 samples placed on steel plates of about 10mm in diameter and 0.25mm in thickness. Managed by a dedicated software that allows to set OSL and TL measurements in sequence. The optical stimulation system consists of infrared and visible LEDs; currently it allows stimulation with blue light (470 ± 30nm, with a maximum power of 36mW/cm² in the sample position). The heating system for thermal stimulation allows reaching the maximum temperature of 700°C. Different optical filters are available to select the frequency range of the emitted luminescence. Housing for a radioactive source (<​sup>​90</​sup>​Sr/<​sup>​90</​sup>​Y or <​sup>​241</​sup>​Am) available for sample calibration. {{:​aree:​epr:​altre_risorse:​lettore_osl-tl_riso_da-20.jpeg?​300 |OSL/TL reader}} OSL/TL reader Risø DA-20 (DTU Nutech, Danimarca) equipped with a carousel loading up to 48 samples placed on steel plates of about 10mm in diameter and 0.25mm in thickness. Managed by a dedicated software that allows to set OSL and TL measurements in sequence. The optical stimulation system consists of infrared and visible LEDs; currently it allows stimulation with blue light (470 ± 30nm, with a maximum power of 36mW/cm² in the sample position). The heating system for thermal stimulation allows reaching the maximum temperature of 700°C. Different optical filters are available to select the frequency range of the emitted luminescence. Housing for a radioactive source (<​sup>​90</​sup>​Sr/<​sup>​90</​sup>​Y or <​sup>​241</​sup>​Am) available for sample calibration.
 +
 \\ \\
 \\ \\
 \\ \\
 +
 === Pulsed Photostimulated Luminescence (PPSL) === === Pulsed Photostimulated Luminescence (PPSL) ===
-{{aree:​epr:​altre_risorse:​lettore_ppsl_suerc.jpeg?​250|}} {{aree:​epr:​altre_risorse:​lettore_ppsl_suerc-dett.jpeg?​250|}} 
-Made by the Scottish Universities Environmental Research Centre (SUERC, Glasgow Scotland) for analysis on irradiated foods. The instrument can be connected to a computer and managed by appropriate software. Equipped with a stimulation system of infrared LEDs. Stimulation occurs by pulses: the duration of the single pulse and the number of pulses can be adjusted by the instrument management software. 
  
-\\<wrap tip>​**[[en:​aree:​epr:​altre_risorse:​luminescenze|About the phenomena of Stimulated Luminescence]]**</​wrap>​+{{aree:​epr:​altre_risorse:​lettore_ppsl_suerc.jpeg?​250 |}} {{aree:​epr:​altre_risorse:​lettore_ppsl_suerc-dett.jpeg?​250 |}} Made by the Scottish Universities Environmental Research Centre (SUERC, Glasgow Scotland) for analysis on irradiated foods. The instrument can be connected to a computer and managed by appropriate software. Equipped with a stimulation system of infrared LEDs. Stimulation occurs by pulses: the duration of the single pulse and the number of pulses can be adjusted by the instrument management software. 
 + 
 +\\ 
 + 
 +<wrap tip>​**[[en:​aree:​epr:​altre_risorse:​luminescenze|About the phenomena of Stimulated Luminescence]]**</​wrap>​ 
 + 
 +\\
  
 > Contacts: > Contacts:
Line 43: Line 53:
 > [[sara.dellamonaca@iss.it|Sara Della Monaca]] > [[sara.dellamonaca@iss.it|Sara Della Monaca]]
 > ☎ **+39 06 4990 2483** > ☎ **+39 06 4990 2483**
 +
 \\ \\
 +
 =====Dosimetric systems===== =====Dosimetric systems=====
 +
 ==== Active dosimeters ==== ==== Active dosimeters ====
-{{aree:​epr:​altre_risorse:​dosimetri_attivi-1.png?​0x150|}} {{aree:​epr:​altre_risorse:​dosimetri_attivi-2.png?​0x150|}}+ 
 +{{aree:​epr:​altre_risorse:​dosimetri_attivi-1.png?​0x150 |}} {{aree:​epr:​altre_risorse:​dosimetri_attivi-2.png?​0x150 |}}
   * Markus ionization chamber type N23343 (PTW)   * Markus ionization chamber type N23343 (PTW)
   * Silicon diode detector for proton beams type DZA192 (Scanditronix)   * Silicon diode detector for proton beams type DZA192 (Scanditronix)
Line 53: Line 67:
   * microDiamond detector type 60019 (PTW)   * microDiamond detector type 60019 (PTW)
   * Electrometer model 6517A (Keithley)   * Electrometer model 6517A (Keithley)
 +
 \\ \\
 +
 ==== Passive dosimeters ==== ==== Passive dosimeters ====
 +
 === Alanine/EPR dosimetry system === === Alanine/EPR dosimetry system ===
-{{:​en:​aree:​epr:​altre_risorse:​alanine.jpg?​250|Alanine/​EPR dosimetry system}}+ 
 +{{:​en:​aree:​epr:​altre_risorse:​alanine.jpg?​200|Alanine/​EPR dosimetry system}} 
 \\ \\
 +
 === Thermoluminescence dosimeters (TLD) === === Thermoluminescence dosimeters (TLD) ===
-{{:​en:​aree:​epr:​altre_risorse:​dosimetri_termoluminescenza.jpeg?​350|Thermoluminescent dosimeters}}+ 
 +{{:​en:​aree:​epr:​altre_risorse:​dosimetri_termoluminescenza.jpeg?​200|Thermoluminescent dosimeters}} 
 \\ \\
 +
 === Radiochromic film dosimeters === === Radiochromic film dosimeters ===
 +
 {{:​en:​aree:​epr:​altre_risorse:​dosimetri_a_film.png?​350|}} {{:​en:​aree:​epr:​altre_risorse:​dosimetri_a_film.png?​350|}}
 +
 \\ \\
 +\\
 +
 ==== Phantoms ==== ==== Phantoms ====
-{{:​en:​aree:​epr:​altre_risorse:​fantocci.png?​300|}}+ 
 +{{:​en:​aree:​epr:​altre_risorse:​fantocci.png?​350 |}}
   * Alderson Rando phantom   * Alderson Rando phantom
   * PMMA phantoms   * PMMA phantoms
   * Water phantoms   * Water phantoms
 +
 \\ \\
 +\\
 +\\
 +
 > Contact: [[cinzia.deangelis@iss.it|Cinzia De Angelis]] > Contact: [[cinzia.deangelis@iss.it|Cinzia De Angelis]]
 > ☎ **+39 06 4990 2248** > ☎ **+39 06 4990 2248**
 +
 +\\
 +
 +===== Surface Plasmon Resonance (SPR - Biacore) =====
 +
 +The <wrap em>​Surface Plasmon Resonance (SPR)</​wrap>​ technique allows studying the interactions between a ligand and putative substates anchored onto a gold-chip, in a pM range of the bulk, with a very high sensibility (few pg/mm²). **[[.:​biacore:​|[...read more]]]**
 +
 +\\
 +
 +> Contact: [[donatella.pietraforte@iss.it|Donatella Pietraforte]]
 +> ☎ **+39 06 4990 2907**
 +> Where I am: building **20**, floor **D**, room **2s**
  
 /* > FIXME **To be revised.**\\ //(remove this paragraph once is finished)// */ /* > FIXME **To be revised.**\\ //(remove this paragraph once is finished)// */