en:aree:citometria:strumentazione:analizzatori [2019/07/22 15:29]
Gianluca Frustagli [CytoFLEX LX - Flow Cytometer] Update.
en:aree:citometria:strumentazione:analizzatori [2019/07/31 14:48] (current)
Gianluca Frustagli FACScan removed.
Line 7: Line 7:
 ===== CytoFLEX LX - Flow Cytometer ===== ===== CytoFLEX LX - Flow Cytometer =====
  
-{{:​aree:​citometria:​strumentazione:​cytoflex_lx.jpeg?​300 }} The CytoFLEX LX flow cytometer is an expansion of the CytoFLEX platform: a unique instrument based on photodiode technology, equipped with 5 lasers, capable of detecting up to 19 fluorescences and 2 scattering parameters simultaneously. ​\\ +{{:​aree:​citometria:​strumentazione:​cytoflex_lx.jpeg?​300 }} The CytoFLEX LX flow cytometer is an expansion of the CytoFLEX platform: a unique instrument based on photodiode technology, equipped with 5 lasers, capable of detecting up to 19 fluorescences and 2 scattering parameters simultaneously. 
-Digital signal processing on 7 decades of dynamic range. ​\\+ 
 +Digital signal processing on 7 decades of dynamic range. 
 Excellent resolution of nanoparticles thanks to the new VSSC parameter. Excellent resolution of nanoparticles thanks to the new VSSC parameter.
  
-=== Technical specifications ===+\\ \\ 
 + 
 +==== Technical specifications ​====
  
   * Resolution:   * Resolution:
-    * < 300 nm particles (488 nm side scattering+    * < 300 nm particles (488 nm side scatter
-    * < 80 nm polystyrene particles (405 nm side scattering)+    * < 80 nm polystyrene particles (405 nm side scatter)
     * rCV 3%     * rCV 3%
   * collections vessels:   * collections vessels:
Line 22: Line 26:
   * absolute counting.   * absolute counting.
  
 +\\
  
-=== Optical configuration ===+==== Optical configuration ​====
  
 5 activated lasers / 19 color parameters: 5 activated lasers / 19 color parameters:
Line 66: Line 71:
 __[[en:​aree:​citometria:​documenti:​pos|Rules for users accredited to the Gallios flow cytometer]]__ __[[en:​aree:​citometria:​documenti:​pos|Rules for users accredited to the Gallios flow cytometer]]__
  
-\\ \\ \\ \\ \\+/* > FIXME **To be revised.**\\ //(remove this paragraph once the translation is finished)// */
  
-===== FACScan - BD Biosciences ===== 
- 
-{{:​aree:​citometria:​strumentazione:​facscan.jpeg?​300 |}} **Technical features ({{:​aree:​citometria:​strumentazione:​facscan-manual.pdf |manual}}):​** 
- 
-  * 1 laser (3 fluorescence) 
-    * 488 nm, 3 PMT 
- 
-\\ \\ \\ \\ \\ \\ \\ \\ 
- 
-/* > FIXME **To be revised.**\\ //(remove this paragraph once the translation is finished)// */