| + | ===== CytoFLEX LX - Flow Cytometer ===== | ||
| + | |||
| + | {{:aree:citometria:strumentazione:cytoflex_lx.jpeg?300 }} The CytoFLEX LX flow cytometer is an expansion of the CytoFLEX platform: a unique instrument based on photodiode technology, equipped with 5 lasers, capable of detecting up to 19 fluorescences and 2 scattering parameters simultaneously. | ||
| + | |||
| + | Digital signal processing on 7 decades of dynamic range. | ||
| + | |||
| + | Excellent resolution of nanoparticles thanks to the new VSSC parameter. | ||
| + | |||
| + | \\ \\ | ||
| + | |||
| + | ==== Technical specifications ==== | ||
| + | |||
| + | * Resolution: | ||
| + | * < 300 nm particles (488 nm side scatter) | ||
| + | * < 80 nm polystyrene particles (405 nm side scatter) | ||
| + | * rCV 3% | ||
| + | * collections vessels: | ||
| + | * 5 ml, 2 ml, 1.5 ml; | ||
| + | * 96w plates; | ||
| + | * absolute counting. | ||
| + | |||
| + | \\ | ||
| + | |||
| + | ==== Optical configuration ==== | ||
| + | |||
| + | 5 activated lasers / 19 color parameters: | ||
| + | |||
| + | ^ **UV Laser** \\ <wrap lo>355 nm</wrap>  ^ **Violet Laser** \\ <wrap lo>405 nm</wrap>  ^  **Blue Laser** \\ <wrap lo>488 nm</wrap>  ^ **Yellow-Green Laser** \\ <wrap lo>561 nm</wrap>  ^ **Red Laser** \\ <wrap lo>640 nm</wrap>  ^ | ||
| + | | 405/30 \\ 525/40 \\ 675/30  | 450/45 \\ 525/40 \\ 610/20 \\ 660/10 \\ 763/43  |  488/8 SSC \\ 525/40 \\ 610/20 \\ 690/50  |  585/42 \\ 610/20 \\ 675/30 \\ 710/50 \\ 763/43  | 660/10 \\ 712/25 \\ 763/43  | | ||
| + | |||
| + | |||
| + | \\ \\ \\ | ||
| + | |||
| ===== LSR II - BD Biosciences ===== | ===== LSR II - BD Biosciences ===== | ||
| Line 19: | Line 53: | ||
| ===== FACSCanto - BD Biosciences ===== | ===== FACSCanto - BD Biosciences ===== | ||
| - | {{:aree:citometria:strumentazione:facscanto.png?300 |}} \\ \\ **Technical features (FIXME brochure):** | + | {{:aree:citometria:strumentazione:facscanto.png?300 |}} \\ \\ **Technical features ({{:aree:citometria:strumentazione:facscanto-brochure.pdf|brochure}}):** | 
| * 2 laser (6 fluorescence) | * 2 laser (6 fluorescence) | ||
| * 488 nm, 4 PMT | * 488 nm, 4 PMT | ||
| Line 35: | Line 69: | ||
| * 633 nm, 3 PMT | * 633 nm, 3 PMT | ||
| - | [[en:aree:citometria:documenti:pos|Norme per gli utenti accreditati al citofluorimetro Gallios]] | + | __[[en:aree:citometria:documenti:pos|Rules for users accredited to the Gallios flow cytometer]]__ | 
| - | \\ \\ \\ \\ \\ | + | /* > FIXME **To be revised.**\\ //(remove this paragraph once the translation is finished)// */ | 
| - | + | ||
| - | ===== FACScan - BD Biosciences ===== | + | |
| - | + | ||
| - | {{:aree:citometria:strumentazione:facscan.jpeg?300 |}} **Technical features ({{:aree:citometria:strumentazione:facscan-manual.pdf |manual}}):** | + | |
| - | * 1 laser (3 fluorescence) | ||
| - | * 488 nm, 3 PMT | ||
| - | |||
| - | \\ \\ \\ \\ \\ \\ \\ \\ | ||
| - | |||
| - | /* > FIXME **To be revised.**\\ //(remove this paragraph once the translation is finished)// */ | ||