Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
en:aree:epr:altre_risorse:start [2020/10/30 18:51]
Paola Fattibene
en:aree:epr:altre_risorse:start [2024/04/19 01:34]
Gianluca Frustagli Added paragraph about "Biacore Unit".
Line 19: Line 19:
  
 ===== Stimulated Luminescence instrumentation ===== ===== Stimulated Luminescence instrumentation =====
 +
 \\ \\
 +
 === Thermoluminescence reader === === Thermoluminescence reader ===
-{{aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-num.jpeg?​300|Thermoluminescence reader + laboratory oven for thermal treatments}} {{:​aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-dett.jpeg?​300|Detail of thermoluminescence reader}} + 
-\\ \\ +{{aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-num.jpeg?​300 |Thermoluminescence reader + laboratory oven for thermal treatments}} {{:​aree:​epr:​altre_risorse:​lettore_termoluminescenza_harshaw3500-dett.jpeg?​300 |Detail of thermoluminescence reader}} Thermoluminescence reader Harshaw, mod. 3500 equipped with software WinREMS for data acquisition and analysis. Thermal cycles up to 600°C (with an uncertainty of +/-1%) with different heating rates, including isothermal decays. Laboratory oven specially designed for TL dosimetry. Run by a microprocessor,​ it allows heating of the sample at controlled temperatures. Different heating cycles available by the dedicated software. 
-\\ Thermoluminescence reader Harshaw, mod. 3500 equipped with software WinREMS for data acquisition and analysis. Thermal cycles up to 600°C (with an uncertainty of +/-1%) with different heating rates, including isothermal decays. Laboratory oven specially designed for TL dosimetry. Run by a microprocessor,​ it allows heating of the sample at controlled temperatures. Different heating cycles available by the dedicated software.+
 \\ \\
 \\ \\
 +
 === Optically stimulated luminescence reader === === Optically stimulated luminescence reader ===
 +
 {{:​aree:​epr:​altre_risorse:​lettore_osl-tl_riso_da-20.jpeg?​300 |OSL/TL reader}} OSL/TL reader Risø DA-20 (DTU Nutech, Danimarca) equipped with a carousel loading up to 48 samples placed on steel plates of about 10mm in diameter and 0.25mm in thickness. Managed by a dedicated software that allows to set OSL and TL measurements in sequence. The optical stimulation system consists of infrared and visible LEDs; currently it allows stimulation with blue light (470 ± 30nm, with a maximum power of 36mW/cm² in the sample position). The heating system for thermal stimulation allows reaching the maximum temperature of 700°C. Different optical filters are available to select the frequency range of the emitted luminescence. Housing for a radioactive source (<​sup>​90</​sup>​Sr/<​sup>​90</​sup>​Y or <​sup>​241</​sup>​Am) available for sample calibration. {{:​aree:​epr:​altre_risorse:​lettore_osl-tl_riso_da-20.jpeg?​300 |OSL/TL reader}} OSL/TL reader Risø DA-20 (DTU Nutech, Danimarca) equipped with a carousel loading up to 48 samples placed on steel plates of about 10mm in diameter and 0.25mm in thickness. Managed by a dedicated software that allows to set OSL and TL measurements in sequence. The optical stimulation system consists of infrared and visible LEDs; currently it allows stimulation with blue light (470 ± 30nm, with a maximum power of 36mW/cm² in the sample position). The heating system for thermal stimulation allows reaching the maximum temperature of 700°C. Different optical filters are available to select the frequency range of the emitted luminescence. Housing for a radioactive source (<​sup>​90</​sup>​Sr/<​sup>​90</​sup>​Y or <​sup>​241</​sup>​Am) available for sample calibration.
 +
 \\ \\
 \\ \\
 \\ \\
 +
 === Pulsed Photostimulated Luminescence (PPSL) === === Pulsed Photostimulated Luminescence (PPSL) ===
-{{aree:​epr:​altre_risorse:​lettore_ppsl_suerc.jpeg?​250|}} {{aree:​epr:​altre_risorse:​lettore_ppsl_suerc-dett.jpeg?​250|}} 
-Made by the Scottish Universities Environmental Research Centre (SUERC, Glasgow Scotland) for analysis on irradiated foods. The instrument can be connected to a computer and managed by appropriate software. Equipped with a stimulation system of infrared LEDs. Stimulation occurs by pulses: the duration of the single pulse and the number of pulses can be adjusted by the instrument management software. 
  
-\\<wrap tip>​**[[en:​aree:​epr:​altre_risorse:​luminescenze|About the phenomena of Stimulated Luminescence]]**</​wrap>​+{{aree:​epr:​altre_risorse:​lettore_ppsl_suerc.jpeg?​250 |}} {{aree:​epr:​altre_risorse:​lettore_ppsl_suerc-dett.jpeg?​250 |}} Made by the Scottish Universities Environmental Research Centre (SUERC, Glasgow Scotland) for analysis on irradiated foods. The instrument can be connected to a computer and managed by appropriate software. Equipped with a stimulation system of infrared LEDs. Stimulation occurs by pulses: the duration of the single pulse and the number of pulses can be adjusted by the instrument management software. 
 + 
 +\\ 
 + 
 +<wrap tip>​**[[en:​aree:​epr:​altre_risorse:​luminescenze|About the phenomena of Stimulated Luminescence]]**</​wrap>​ 
 + 
 +\\
  
 > Contacts: > Contacts:
Line 43: Line 53:
 > [[sara.dellamonaca@iss.it|Sara Della Monaca]] > [[sara.dellamonaca@iss.it|Sara Della Monaca]]
 > ☎ **+39 06 4990 2483** > ☎ **+39 06 4990 2483**
 +
 \\ \\
 +
 =====Dosimetric systems===== =====Dosimetric systems=====
 +
 ==== Active dosimeters ==== ==== Active dosimeters ====
-{{aree:​epr:​altre_risorse:​dosimetri_attivi-1.png?​0x150|}} {{aree:​epr:​altre_risorse:​dosimetri_attivi-2.png?​0x150|}}+ 
 +{{aree:​epr:​altre_risorse:​dosimetri_attivi-1.png?​0x150 |}} {{aree:​epr:​altre_risorse:​dosimetri_attivi-2.png?​0x150 |}}
   * Markus ionization chamber type N23343 (PTW)   * Markus ionization chamber type N23343 (PTW)
   * Silicon diode detector for proton beams type DZA192 (Scanditronix)   * Silicon diode detector for proton beams type DZA192 (Scanditronix)
Line 53: Line 67:
   * microDiamond detector type 60019 (PTW)   * microDiamond detector type 60019 (PTW)
   * Electrometer model 6517A (Keithley)   * Electrometer model 6517A (Keithley)
 +
 \\ \\
 +
 ==== Passive dosimeters ==== ==== Passive dosimeters ====
 +
 === Alanine/EPR dosimetry system === === Alanine/EPR dosimetry system ===
-{{:​en:​aree:​epr:​altre_risorse:​alanine.jpg?​250|Alanine/​EPR dosimetry system}}+ 
 +{{:​en:​aree:​epr:​altre_risorse:​alanine.jpg?​200|Alanine/​EPR dosimetry system}} 
 \\ \\
 +
 === Thermoluminescence dosimeters (TLD) === === Thermoluminescence dosimeters (TLD) ===
-{{:​en:​aree:​epr:​altre_risorse:​dosimetri_termoluminescenza.jpeg?​350|Thermoluminescent dosimeters}}+ 
 +{{:​en:​aree:​epr:​altre_risorse:​dosimetri_termoluminescenza.jpeg?​200|Thermoluminescent dosimeters}} 
 \\ \\
 +
 === Radiochromic film dosimeters === === Radiochromic film dosimeters ===
 +
 {{:​en:​aree:​epr:​altre_risorse:​dosimetri_a_film.png?​350|}} {{:​en:​aree:​epr:​altre_risorse:​dosimetri_a_film.png?​350|}}
 +
 \\ \\
 +\\
 +
 ==== Phantoms ==== ==== Phantoms ====
-{{:​en:​aree:​epr:​altre_risorse:​fantocci.png?​300|}}+ 
 +{{:​en:​aree:​epr:​altre_risorse:​fantocci.png?​350 |}}
   * Alderson Rando phantom   * Alderson Rando phantom
   * PMMA phantoms   * PMMA phantoms
   * Water phantoms   * Water phantoms
 +
 \\ \\
 +\\
 +\\
 +
 > Contact: [[cinzia.deangelis@iss.it|Cinzia De Angelis]] > Contact: [[cinzia.deangelis@iss.it|Cinzia De Angelis]]
 > ☎ **+39 06 4990 2248** > ☎ **+39 06 4990 2248**
 +
 +\\
 +
 +===== Surface Plasmon Resonance (SPR - Biacore) =====
 +
 +The <wrap em>​Surface Plasmon Resonance (SPR)</​wrap>​ technique allows studying the interactions between a ligand and putative substates anchored onto a gold-chip, in a pM range of the bulk, with a very high sensibility (few pg/mm²). **[[.:​biacore:​|[...read more]]]**
 +
 +\\
 +
 +> Contact: [[marcello.belfiore@iss.it|Marcello Belfiore]]
 +> ☎ **+39 06 4990 3046**
 +> Where I am: building **10**, floor **D**, room **9**
  
 /* > FIXME **To be revised.**\\ //(remove this paragraph once is finished)// */ /* > FIXME **To be revised.**\\ //(remove this paragraph once is finished)// */