Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:aree:citometria:strumentazione:analizzatori [2019/07/22 15:29] Gianluca Frustagli [CytoFLEX LX - Flow Cytometer] Update. |
en:aree:citometria:strumentazione:analizzatori [2019/07/31 14:48] (current) Gianluca Frustagli FACScan removed. |
||
---|---|---|---|
Line 7: | Line 7: | ||
===== CytoFLEX LX - Flow Cytometer ===== | ===== CytoFLEX LX - Flow Cytometer ===== | ||
- | {{:aree:citometria:strumentazione:cytoflex_lx.jpeg?300 }} The CytoFLEX LX flow cytometer is an expansion of the CytoFLEX platform: a unique instrument based on photodiode technology, equipped with 5 lasers, capable of detecting up to 19 fluorescences and 2 scattering parameters simultaneously. \\ | + | {{:aree:citometria:strumentazione:cytoflex_lx.jpeg?300 }} The CytoFLEX LX flow cytometer is an expansion of the CytoFLEX platform: a unique instrument based on photodiode technology, equipped with 5 lasers, capable of detecting up to 19 fluorescences and 2 scattering parameters simultaneously. |
- | Digital signal processing on 7 decades of dynamic range. \\ | + | |
+ | Digital signal processing on 7 decades of dynamic range. | ||
Excellent resolution of nanoparticles thanks to the new VSSC parameter. | Excellent resolution of nanoparticles thanks to the new VSSC parameter. | ||
- | === Technical specifications === | + | \\ \\ |
+ | |||
+ | ==== Technical specifications ==== | ||
* Resolution: | * Resolution: | ||
- | * < 300 nm particles (488 nm side scattering) | + | * < 300 nm particles (488 nm side scatter) |
- | * < 80 nm polystyrene particles (405 nm side scattering) | + | * < 80 nm polystyrene particles (405 nm side scatter) |
* rCV 3% | * rCV 3% | ||
* collections vessels: | * collections vessels: | ||
Line 22: | Line 26: | ||
* absolute counting. | * absolute counting. | ||
+ | \\ | ||
- | === Optical configuration === | + | ==== Optical configuration ==== |
5 activated lasers / 19 color parameters: | 5 activated lasers / 19 color parameters: | ||
Line 66: | Line 71: | ||
__[[en:aree:citometria:documenti:pos|Rules for users accredited to the Gallios flow cytometer]]__ | __[[en:aree:citometria:documenti:pos|Rules for users accredited to the Gallios flow cytometer]]__ | ||
- | \\ \\ \\ \\ \\ | + | /* > FIXME **To be revised.**\\ //(remove this paragraph once the translation is finished)// */ |
- | ===== FACScan - BD Biosciences ===== | ||
- | |||
- | {{:aree:citometria:strumentazione:facscan.jpeg?300 |}} **Technical features ({{:aree:citometria:strumentazione:facscan-manual.pdf |manual}}):** | ||
- | |||
- | * 1 laser (3 fluorescence) | ||
- | * 488 nm, 3 PMT | ||
- | |||
- | \\ \\ \\ \\ \\ \\ \\ \\ | ||
- | |||
- | /* > FIXME **To be revised.**\\ //(remove this paragraph once the translation is finished)// */ |